J&D’s new Micro-accuracy flexible rogowski coil (CT coil) measures even sensitive error to use special magnetic winding technology with small size. It is very effective for small sized AC measuring utility since it reduces chronically affected errors on existed Rogowski coil by conductor’s position.
Summary:
• Input: 250A-500Aac
• Output: 333mVac, 0-5Vdc, 4-20mAdc
• Sizes: 55mm (click here to view our 35mm, 80mm or 105mm coils)
• Connection: 2m shielded lead wires
• Form factor: Rogowski flexible core
Applications
• Very high current monitoring
• DC ripple measurement
• Harmonics and transients monitoring
• Power monitoring & control systems
• Applicable in eletronic Watt-hour meter
Features
• Ø55mm sensing aperture for non-contact measurement
• Very low position sensitivity
• No danger from open-circuited secondary
• High secondary output voltage & precise linearity error
• Isolated plastic case recognized according to UL94-V0
Lead Time
• 4 weeks